Sensors monitor pressure values in real time to ensure consistency and process requirements, using high-precision flat-type, spoke-type, and thin-planar sensors to prevent cell damage and loose cells.
Product Description of X-B-D150 Series
Sensors are used to monitor the pressure value when pressing down and holding pressure in real time to ensure that the pressure value is consistent and in line with the process requirements. Avoid too much or too little pressure, resulting in cell damage, loose cells, and other problems. High-precision flat-type sensors, spoke-type sensors, and thin-planar pressure sensors are generally chosen.
Product Features and Advantages of X-B-D150 Series
The X-B-D150 Series is a type of sensor used for monitoring pressure values. It can real-time monitor the pressure value when pressing down and holding pressure to ensure consistency with process requirements. It helps to avoid excessive or insufficient pressure, which can lead to cell damage, loose cells, and other issues. Typically, high-precision flat-type sensors, spoke-type sensors, and thin-planar pressure sensors are chosen for this series.
The X-B-D150 Series offers the following advantages:
The technical parameters of the X-B-D150 Series demonstrate its high precision, stability, and reliability. It is suitable for various applications that require pressure monitoring, such as industrial production, medical equipment, and laboratories. Whether in high-temperature, low-temperature, or harsh environments, the X-B-D150 Series can provide accurate and reliable pressure monitoring results, ensuring process stability and safety.
Technical Parameter of X-B-D150 Series
Material |
Stainless steel |
Rated output |
2.0±10%mV/V |
Zero balance |
±2%F.S. |
Non-linearity |
0.2%F.S. |
Hysteresis |
0.2%F.S. |
Repeatability |
0.1%F.S. |
Creep(30 min) |
0.2%F.S. |
Temp effect on output |
0.05%F.S./10°C |
Temp effect on zero |
0.05%F.S./10°C |
Input impedance |
1080±30Ω |
Output impedance |
1000±5Ω |
Insulation |
≥5000MΩ/100VDC |
Recommended excitation |
5-10VDC |
Maximum excitation |
15VDC |
Compensated temp range |
-10~40°C |
Operating temp range |
-20~80°C |
Limit load |
150% |
Breaking load |
200% |
Cable size |
φ5×4m |
Life |
Full scale more than 1 million times |
Cable Connection |
Ex+: Red;Ex-: Black;Sig+: Green;Sig-: White |
Dimensions
Capacity | 5T | 10T | 15T | 20T | 25T | 30T |
Load Direction & Wiring Code