The X-TS08-L200-W135-H17 Series is a high-precision resistance strain gauge product that offers strong resistance to partial load, good temperature characteristics with high and low temperature compensation, easy installation and use, and a high dynamic response frequency.
Product Description of X-TS08-L200-W135-H17 Series
The X-TS08-L200-W135-H17 Series is a range of high-precision resistance strain gauges designed for measuring weights of different capacities, including 3000kg, 5000kg, 8000kg, and 10000kg. These gauges feature an accuracy class of Level 3 and are equipped with advanced weighing indicators. The operating temperature ranges from -10°C to +80°C, while the scale and sensor can operate within a temperature range of -20°C to +80°C. The relative humidity should not exceed 95% and should be non-condensing. The product is powered by a 9V/800MA PA or rechargeable lithium battery and has a protection class of IP65.
Product Features of X-TS08-L200-W135-H17 Series
Product Advantages of X-TS08-L200-W135-H17 Series
Technical Parameter of X-TS08-L200-W135-H17 Series
Material |
Alloy steel |
Rated output |
2.0±10%mV/V |
Zero balance |
±2%F.S. |
Non-linearity |
≤±0.1%F.S. |
Hysteresis |
≤±0.1%F.S. |
Repeatability |
≤±0.1%F.S. |
Creep(30 min) |
≤±0.1%F.S. |
Temp effect on output |
0.2%F.S./10°C |
Temp effect on zero |
0.2%F.S./10°C |
Input impedance |
350±5Ω |
Output impedance |
350±5Ω |
Insulation |
≥5000MΩ/100VDC |
Recommended excitation |
5V |
Maximum excitation |
10VDC |
Compensated temp range |
-10~40°C |
Operating temp range |
-20~80°C |
Limit load |
150% |
Breaking load |
200% |
Cable size |
φ3×4m |
Life |
Full scale more than 1 million times |
Cable Connection |
Ex+: Red;Ex-: Black;Sig+: Green;Sig-: White |
Dimensions
Load Direction & Wiring Code
Product Application
Sensors are used to monitor the pressure value when pressing down and holding pressure in real time to ensure that the pressure value is consistent and in line with the process requirements. Avoid too much or too little pressure, resulting in cell damage, loose cells, and other problems. High-precision flat-type sensors, spoke-type sensors, and thin-planar pressure sensors are generally chosen.